  • 汇流箱 室内正.png
  • 汇流箱 室内侧1.png
  • 汇流箱 室内侧2.png
  • 汇流箱 室外 正.png
  • 汇流箱 室外 侧1.png
  • 汇流箱 室外 侧2.png

Photovoltaic combiner box


Photovoltaic Combiner Box—Image Showcase and Overview This product is primarily used for current collection in centralized photovoltaic grid-connected power generation systems, connecting string inverters. It is installed between the string inverters and the grid-connected metering cabinet. The product features protection functions such as input surge protection and system overcurrent protection. By reducing long-distance cable transmission, this product helps users lower costs and improve system efficiency. The product has passed industry-standard certifications including CCC certification, CE certification, and ISO9001 quality management system certification. Product Details—Key Features: All components are sourced from well-known domestic and international brands and have been certified by authoritative institutions with complete qualifications. Exposed live parts inside the box are protected by transparent covers made of flame-retardant, antistatic, and high-temperature-resistant materials. Both incoming and outgoing circuit breakers are installed vertically facing forward and laid flat within the enclosure, with wiring connections clearly labeled to prevent miswiring. The main busbar is connected using copper bars, and the surface of these bars is treated with a tin-plating process that provides corrosion and oxidation resistance. Each phase conductor is marked with universally recognized colors for easy identification and high visibility. An optional intelligent monitoring system is available, providing real-time data on system voltage, main busbar current, switch status, and lightning protection status. The product is suitable for various voltage levels in the industry: 380VAC, 480VAC, 540VAC. It features a rainproof enclosure design for outdoor installation. Customization of special requirements and functions is supported. Technical Parameters: Product Model: JXF Common String Inverter Power Ranges: 5, 10, 15, 20, 25, 30, 40, 50, 60, 80, 100, 110, 125, 175 kW Inverter Input Channels: 1 to N channels (customizable as needed) Total AC Output Channels: 1 channel Collection System Voltage (optional): AC: 220V, AC: 380V, AC: 540V, AC: 800V Branch Circuit Breaker Ratings (optional): 32A, 63A, 80A, 100A, 125A, 160A, 200A, 250A, 400A, 630A, 800A Switch Brand (optional): Delixi, Chint, Changshu, Liangxin, ABB, Schneider Protection Functions: Short-circuit protection Overload protection Lightning protection (nominal current: In: 20KA, Imax: 40KA, Up ≤ 4kV) Lightning protection failure protection Environmental Adaptability: Operating temperature range: -25°C to +60°C Storage temperature range: -40°C to +70°C Humidity range: 0–90%, no condensation, frost-free, and free from corrosive or oily gases (please specify if applicable). Product Model: JXF Usage Altitude: ≤ 2000 m Safety Standards: Busbar Material: Pure copper busbar (industrial-grade, tinned) Safety Protection: PVC protective panels Electrical Clearance: ≥ 14 mm Creepage Distance: ≥ 25 mm Insulation Resistance: > 20 MΩ Insulation Voltage: AC 3000V, 1 minute Typical Parameters: Enclosure Material: Stainless steel, cold-rolled steel with powder coating, or stainless steel with powder coating Enclosure Rating: Outdoor IP65 Enclosure Type: Single-door distribution box Installation Method: Wall-mounted or floor-standing (customizable) Enclosure Dimensions (Length × Width × Height): Customized as required AC Combiner Box Wiring Diagram and Layout Diagram

Category:

PV New Energy Grid Cabinet


This product is primarily used for collecting power from string inverters in centralized photovoltaic grid-connected power generation systems. It is connected in series between the string-type grid-connected inverter and the grid-metering cabinet. The product features protections such as input surge protection and overcurrent protection for the system. By reducing the need for long-distance transmission of large cable runs, this product helps users lower costs and improve system efficiency. The product has obtained industry-standard certifications including CCC certification, CE certification, and ISO9001 quality management system certification.

Main features

All components are sourced from well-known domestic and international brands, certified by authoritative institutions, and fully qualified. Exposed live parts inside the enclosure are protected by transparent covers made of flame-retardant, antistatic, and high-temperature-resistant materials. Both incoming and outgoing circuit breakers are installed vertically facing forward and laid flat within the enclosure, with wiring connections precisely matched to avoid miswiring. The main busbars are connected using copper bars, whose surfaces have undergone a tinning process that provides corrosion and oxidation resistance. Each phase conductor is marked with colors commonly used in the industry for clear and conspicuous identification. An optional smart monitoring system is available, providing real-time data on system voltage, main busbar current, switch status, and lightning protection status. This product is suitable for various voltage levels in the industry: 380Vac, 480Vac, and 540Vac. It features a rainproof cover design, making it ideal for outdoor installation.

Supports special requirements and custom feature development.

Technical Parameters

Product Model

JXF

Common string inverter power

5, 10, 15, 20, 25, 30, 40, 50, 60,

80, 100, 110, 125, 175 kW

Inverter input channels

Route 1 to Route N (customized on demand)

Total number of AC output channels

Route 1

Convergence requirements

Single-phase and three-phase busbar assembly

System voltage (optional)

AC: 220V, AC: 380V, AC: 540V, AC: 800V

Branch circuit switch housing (optional)

32A, 63A, 80A, 100A, 125A, 160A

200A, 250A, 400A, 630A, 800A

Switch brand (optional)

Delixi, Chint, Changshu, Liangxin, ABB, Schneider

Protection function

 

Short-circuit protection

There is

Overload protection

There is

Lightning protection

With (nominal current: In: 20 kA, Imax: 40 kA, Up ≤ 4 kV)

Lightning protection failure protection

There is

Environmentally suitable

 

Temperature and humidity

Operating temperature: -25 to +60℃

Storage temperature: -40 to +70℃

Humidity: 0-90% with no condensation or frost

Areas free of corrosive gases (please specify if any exist)

Product Model

JXF

Use altitude

≤2000M

Safety regulations

Copper Busbar Selection

Copper busbar (tin-plated industrial)

Security protection

PVC protective board

Electrical clearance

≥14mm

Creepage distance

≥25mm

Insulation resistance

>20 MΩ

Insulation voltage

AC 3000V, 1 MIN

Regular parameters

Box material

Stainless steel, cold-rolled sheet with plastic coating, stainless steel with plastic coating

Protection level

Outdoor IP65

Box type

Single-door distribution box

Installation method

Wall-mounted / Floor-standing (customizable)

Box dimensions (length × width × height)

Customized on demand