GZDW Intelligent High-Frequency Switching DC Power Supply
Category:
Low-Voltage Switchgear
Tel:
E-mail:
Introduction
Product Overview
The GZDW intelligent high-frequency switch DC power supply (microcomputer-controlled) is applicable to large, medium, and small power plants and substations, serving as the DC power source required for high-voltage switchgear operation—both under normal conditions and during fault situations—as well as for relay protection, automatic control, emergency lighting, visual and audible signaling, and other related functions. It can also be used in industries such as metallurgy, railways, mining, petrochemicals, postal and telecommunications, communications, healthcare, banking, hotels, high-rise buildings, and computer networks to provide the necessary DC power. The microcomputer-controlled DC power supply cabinet is suitable for power plants, substations, and other industrial applications that require unattended operation and centralized remote monitoring. This product complies with [relevant standards].
JB/T5777.4-2000 Standard “General Technical Specifications and Safety Requirements for DC Power Supply Equipment in Power Systems.”
Model and Meaning

Main Technical Parameters
◆ 1. Input power supply voltage: Three-phase AC 380V ± 10%, 50Hz ± 5%;
◆ 2. Rated output DC voltage: 48V; 110V; 220V;
◆ 3. Rated output DC current: 5A, 8A, 10A, 15A, 20A, 30A, 40A, 50A;
◆ 4. Battery rated capacity: 10Ah, 20Ah, 38Ah, 40Ah, 50Ah, 60Ah, 65Ah, 100Ah, 150Ah, 200Ah, 250Ah, 300Ah (Note: Special cases can be negotiated).
◆ 5. Voltage adjustment range:
| Voltage Adjustment Table Range | |||
| Output DC voltage rating | 48V | 110V | 220V |
| Floating voltage adjustment range | 43 ~ 57 | 99 ~ 130 | 198 ~ 260 |
| Equalization Charge Voltage Adjustment Range | 54 ~ 62 | 125 ~ 140 | 198 ~ 286 |
| Main charging voltage adjustment range | 43 ~ 70 | 99 ~ 162 | 187 ~ 310 |
◆ 6. Output DC current adjustment range: 0 to 100% of the rated value;
◆ 7. Voltage regulation accuracy: <± 1%;
◆ 8. Current regulation accuracy: < ±1%;
◆ 9. Operating Mode: Continuous operation;
◆ 10. Efficiency: >90%;
◆ 11. Protection rating: IP20-HP30.
Operating environment conditions
◆ 1. Altitude: 2,000 meters and below (for altitudes exceeding 2,000 meters, please consult with our company for a solution);
◆ 2. Ambient temperature: -5 ℃ ~ 40 ℃;
◆ 3. Relative humidity: The daily average shall not exceed 85% (+25℃);
◆ 4. Special circumstances can be resolved through negotiation with the company.
◆ 5. The applicable scope for different specifications is shown in the table below:
| Product Model | Serial Number Description | Specification (Type) Applicable Scope |
| GZDW-30-mouth/mouth | Single battery group, single busbar with sectionalization, two dual-line output charging and float charging units, no step-down circuit. | 10 Power plant or large substation |
| GZDW-31-mouth/mouth | Single-battery group, single busbar, two-unit dual-wire output charging and float-charge device—no step-down circuit. | 10 Power plant or large substation |
| GZDW-32-mouth/mouth | Single-battery group, single-busbar sectioning, and two dual-line output charging and float-charge units. | 20 12kV–220kV substations and small- and medium-sized power plants |
| GZDW-33-mouth/mouth | Single-battery group, dual-busbar, two-unit dual-line output charging and float-charge device | 20 12kV-220kV substations and small- and medium-sized power plants |
| GZDW-34-mouth/mouth | Single-battery group, dual-busbar sectionalized design, and two three-phase output charging float charger. | 20 12kV-220kV substations and small- and medium-sized power plants |
| GZDW-35-mouth/mouth | Single-battery group, dual-bus, two-unit three-wire output float charging device | 20 12kV-220kV substations and small-to-medium-sized power plants |
| GZDW-40-mouth/mouth | Dual-battery system, single busbar section, two dual-line output charging and float-charge units, no step-down circuit. | 10 Important power plants or large substations |
| GZDW-41-mouth/mouth | Dual-battery configuration, dual-bus sectionalization, and three dual-line output float charging units. | 12 12kV-220kV substations and small- and medium-sized power plants |
| GZDW-42-mouth/mouth | Single-battery group, dual-bus sectionalization, and three double-line output charging and float charging units. | 10 Important power plants or large substations |
| GZDW-43-mouth/mouth | Single-battery group, dual-busbar, two-unit dual-line output charging and float-charge device | 12 12kV-220kV substations and small- and medium-sized power plants |